Association between stent fracture and restenosis after drug-eluting stent implantation
10.3760/cma.j.issn.0253-3758.2009.01.006
- VernacularTitle:药物洗脱支架置人术后断裂导致支架内再狭窄的临床分析
- Author:
Feng TIAN
1
;
Yun-Dai CHEN
;
Zhi-Jun SUN
;
Chang-Fu LIU
;
Ting-Shu YANG
;
Xian-Tao SONG
Author Information
1. 首都医科大学附属北京安贞医院
- Keywords:
Coronary disease;
Stents;
Coronary restenosis
- From:
Chinese Journal of Cardiology
2009;37(1):35-38
- CountryChina
- Language:Chinese
-
Abstract:
objective This study Wag performed to evaluate the relationship between the stent fracture and restenosis after drug-eluting stent implantation.Methods The study enrolled 536 patients with and BMS group(n=139).The coronary angiography images were analyzed to detect restenosis and stent fracture.Results Restenosis rate was significantly lower in DES group(31/397,7.8%)compared that in BMS group(30/139,21.6%,P<0.05).Stent fracture(n=5)was found only in DES group and not in BMS group(P<0.05).Restenosis Were found in all stent fracture segments.The stent fracture developed at the angulated tortuosity lesions.Conclusion Stent fracture is one of the causes of restenosis after drug-eluting stents implantation and related to implantation of long DES stent at tlle location of angulated tortuosity lesions.