The corrosion of pure iron in five different mediums.
- Author:
Li XU
1
;
Shengfa ZHU
;
Nan HUANG
;
Xinchang LI
;
Yu ZHANG
Author Information
1. Key Lab. of Advanced Technology of Materials (Chinese Education Ministry), Southwest Jiaotong University, Chengdu 610031, China.
- Publication Type:Journal Article
- MeSH:
Biocompatible Materials;
chemistry;
Body Fluids;
metabolism;
Corrosion;
Iron;
chemistry;
Isotonic Solutions;
chemistry;
Materials Testing;
Sodium Chloride;
chemistry
- From:
Journal of Biomedical Engineering
2009;26(4):783-786
- CountryChina
- Language:Chinese
-
Abstract:
The sectional test was adopted in this study to investigate the corrosion of pure iron in 0.15 mol/L NaCl solution, Ringer solution, PBS(-) solution, SBF solution and M199 cell culture medium at three different times. The result shows that different mediums have different corrosion effects on pure iron. The arrangement according to the medium's corrosion ability from the strongest to weakest is 0.15 mol/L NaCl solution (Ringer solution), PBS(-) solution, SBF solution and M199 cell culture medium. The results of scanning electron microscopy and energy dispersive X-ray spectrum analyses show that the addition of HPO4(2-), H2POC4-, Ca2+, Mg2+, SO4(2-) and the organic component can inhibit the corrosion to some degree.