Visualization of Medpor implants using surface rendering.
- Author:
Meng WANG
1
;
Lai GUI
;
Xiao-Jing LIU
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Female; Humans; Imaging, Three-Dimensional; Male; Polyethylenes; Skull; diagnostic imaging; surgery; Tomography, X-Ray Computed; methods; Young Adult
- From: Chinese Medical Journal 2011;124(18):2890-2893
- CountryChina
- Language:English
-
Abstract:
BACKGROUNDThe Medpor surgical implant is one of the easiest implants in clinical practice, especially in craniomaxillofacial surgery. It is often used as a bone substitute material for the repair of skull defects and facial deformities. The Medpor implant has several advantages but its use is limited because it is radiolucent in both direct radiography and conventional computed tomography, causing serious problems with visualization.
METHODSIn this study, a new technique for visualizing Medpor implants was evaluated in 10 patients who had undergone facial reconstruction using the material. Continuous volume scans were made using a 16-channel tomographic scanner and 3D reconstruction software was used to create surface renderings. The threshold values for surface renderings of the implant ranged from -70 HU to -20 HU, with bone as the default.
RESULTSThe shape of the implants and the spatial relationship between bone and implant could both be displayed.
CONCLUSIONSurface rendering can allow successful visualization of Medpor implants in the body.