Investigation on occupational exposure to 5-fluorouracil in pharmacy intravenous admixture service of a hospital.
- Author:
Yu-wen HUANG
1
;
Nian-hua ZHANG
;
Dong-mei TONG
;
Xuan FENG
;
Mei-bian ZHANG
;
Ji-liang HE
Author Information
- Publication Type:Journal Article
- MeSH: Antineoplastic Agents; analysis; Drug Administration Routes; Fluorouracil; analysis; Humans; Occupational Exposure; Pharmacy Service, Hospital
- From: Chinese Journal of Industrial Hygiene and Occupational Diseases 2010;28(6):414-417
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo investigate the level of occupational exposure to 5-fluorouracil (5-Fu) in the pharmacy intravenous admixture service (PIVAS) of a hospital, and identify the sources of 5-Fu contamination.
METHODSThe 5-Fu concentrations in air, on the surface of different areas in PIVAS and personal protective equipments were detected using UV-vis spectrophotometry.
RESULTSThe 5-Fu in air could not be detected. The 5-Fu concentrations on five different surfaces of biological safety cabinets were (22.00 +/- 6.35), (13.99 +/- 2.46), (14.13 +/- 0.72), (7.25 +/- 1.19) and (9.87 +/- 1.23) ng/cm2, respectively, which were significantly higher than those [(3.14 +/- 0.04), (5.43 +/- 0.65), (2.26 +/- 0.17), (2.26 +/- 0.17) and (3.63 +/- 0.46) ng/cm2] of corresponding controls (P < 0.05 or P < 0.01). The 5-Fu concentrations of the floor under cabinets [(18.19 +/- 5.22) ng/cm2], the floor in front of cabinets [(10.25 +/- 2.57)ng/cm2], the office floor [(11.64 +/- 2.53) ng/cm2], the terrace floor [(99.89 +/- 14.06 ) ng/cm2], the floor beside trash can in dressing room [(24.54 +/- 0.23) ng/cm2] were significantly higher than those of control [(3.36 +/- 0.11 ) ng/cm2] (P < 0.05 or P < 0.01). The 5-Fu concentrations of the tables in preparation room [(7.22 +/- l.04) ng/cm2] and the tables in office [(11.81 +/- 1.18) ng/cm2] were significantly higher than those of control [(5.56 +/- 0.14) ng/cm2] (P < 0.05 or P < 0.01). The 5-Fu concentrations of the indoor handle in preparation room were significantly higher than those of controls (P < 0.05 or P < 0.01). 5-Fu concentrations on the surfaces of outdoor handle and floor beside door in preparation room were not significantly increased compared with controls (P > 0.05). The 5-Fu concentrations on the surfaces of infusion bags, transfer box, transfer trays were significantly higher than those of controls (P < 0.05). The differences of 5-Fu concentrations between outer and inner masks and controls were not significant (P > 0.05). The 5-Fu concentrations of gloves of preparing and checking staffs were significantly higher than those of controls (P < 0.05 or P < 0.01).
CONCLUSIONThe preparing and checking process of 5-Fu and the treatment of medical wastes are major sources of 5-Fu contamination.