Clinical value of double respiratory navigator-gated high-resolution black-blood coronary artery wall magnetic resonance imaging.
- Author:
Hai-yue JU
1
;
Li YANG
;
Liu-quan CHENG
;
Zu-long CAI
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Coronary Vessels; anatomy & histology; Female; Humans; Magnetic Resonance Imaging; methods; Male; Middle Aged; Young Adult
- From: Acta Academiae Medicinae Sinicae 2013;35(3):305-310
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo explore the value of phase ordering with automatic window selection(PAWS)and simultaneous multiple volume(SMV)algorithm double respiratory navigator-gated two-dimensional(2DNAV)dual inversion recovery(DIR)fast spin echo(FSE)high-resolution black-blood coronary artery wall magnetic resonance imaging(MRI)and evaluate its advantages and limitations.
METHODSPAWS and SMV 2DNAV DIR FSE high-resolution black-blood MRI was performed in 21 healthy volunteers. The images were evaluated qualitatively by using four grades(grade 0can not evaluate;grade 1bad;grade 2good;grade 3perfect). Images defined as grade 0 and grade 1 were excluded and those defined as grade 2 and 3 were evaluated further. Thickness of proximal(or middle)segment of right coronary artery(RCA)and left anterior descending branch(LAD)were measured. The difference of wall thickness was analyzed by using two-tailed independent sample t-test. P values of less than 0.05 were considered statistically significant.
RESULTSAmong the 38 slice images,31 slices(RCA13 slices,LAD18 slices;grade 214 slices,grade 317 slices)were obtained for further evaluation. The mean thickness of RCA and LAD was(0.94±0.16)and(0.89±0.15)mm,respectively,and the difference was not significant(t=-0.790,P>0.05).
CONCLUSIONPAWS and SMV algorithm 2DNAV DIR FSE high-resolution black-blood MRI has certain clinical value for coronary artery wall imaging.