Risk Factors for Cataract Formation after Implantable Collamer Lens Implantation: Over a Mean 7.5-Year Follow-Up Period.
10.3341/jkos.2015.56.6.835
- Author:
Damho LEE
1
;
Ju Yong SEOK
;
Hak Su KYUNG
;
Joon Mo KIM
Author Information
1. Vision Eye Center, Seoul, Korea. damholee@naver.com
- Publication Type:Original Article
- Keywords:
Cataract formation;
ICL implantation;
Peripheral touch;
Risk factors
- MeSH:
Cataract*;
Follow-Up Studies*;
Incidence;
Lens, Crystalline;
Risk Factors*
- From:Journal of the Korean Ophthalmological Society
2015;56(6):835-846
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
PURPOSE: To determine the risk factors and incidence of cataract formation over a long-term mean follow-up of 7.5 years after type V4 implantable collamer lens (ICL) implantation. METHODS: We analyzed the preoperative, 3-month postoperative, 3-year postoperative, and last follow-up data of 228 eyes (118 patients) with mean preoperative spherical equivalent of -12.7 D and minimum postoperative follow-up of 3 years. Additionally, we determined the risk factors for cataract formation and calculated the 10.3 year cumulative cataract formation rate and 10.3 year cumulative cataract surgery rate using a survival curve. RESULTS: After type V4 ICL implantation with minimum follow-up of 3 years, the calculated 10.3 year cumulative cataract formation rate was 20% and actual cataracts developed in 34 eyes (14.9%). The 10.3 year cumulative cataract surgery rate was 12% based on a survival curve and actual cataract surgery was performed in 12 eyes (5.3%). The risk factors for cataract formation were age (odds ratio [OR] = 1.10, p = 0.00), preoperative spherical equivalent (OR = 0.90, p = 0.00), crystalline lens thickness (OR = 9.54, p = 0.00), axial length (OR = 1.33, p = 0.00), 3 months postoperative vault (OR = 0.50, p = 0.03), and existence of peripheral touch between ICL optic margin and crystalline lens at last follow-up (OR = 7.84, p = 0.00). CONCLUSIONS: We suggest one of the main risk factors for cataract formation after ICL implantation is decreased central vault and peripheral touch between ICL optic margin and crystalline lens.