The effects of infrasound on the blood coagulation function of guinea pigs.
- Author:
Wen-min MA
1
;
Peng QI
;
Jian-zhong ZHANG
;
Yong YI
;
Xing-ming CHEN
;
Jun ZHANG
;
Rui-gang HAN
Author Information
- Publication Type:Journal Article
- MeSH: Animals; Blood Coagulation; Blood Physiological Phenomena; Female; Guinea Pigs; Male; Nitric Oxide; blood; Noise; adverse effects; Prothrombin Time
- From: Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(3):209-211
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo study the change of the blood coagulation function of guinea pigs exposed to 16 Hz/120 dB, 16 Hz/125 dB infrasound and to explore the mechanism of circulation system damage.
METHODSSeventy-two guinea pigs were divided into 3 groups: the control group, the group exposed to 16 Hz/120 dB infrasound for 1.5 h a day and the group exposed to 16 Hz/125 dB infrasound for 1.5 h a day. Each exposure group was divided into 4 sub-groups (8 guinea pigs a sub-group) which were exposed to infrasound for 1, 7, 14 and 21 d, respectively. The coagulation function and serum nitric oxide (NO) were measured for control group and all sub-groups after exposure to infrasound.
RESULTSThe prothrombin time (PT), international normalized ratio (INR) and serum NO of group exposed to 16 Hz/125 dB infrasound were (31.16 ± 3.05) s, 2.53 ± 1.21 and (88.304 ± 52.601) µmol/L, respectively, which were significantly higher than those [(21.36 ± 0.10) s, 1.65 ± 0.07 and (30.943 ± 26.864) µmol/L] of control group (P < 0.05). PT and INR of sub-groups exposed to 16 Hz/125 dB infrasound for 14 and 21 d were significantly higher than those of control group. NO of sub-groups exposed to 16 Hz/125 dB infrasound for 1 week and 2 weeks were significantly higher than that of control group (P < 0.05), but NO of sub-group exposed to 16 Hz/125 dB infrasound for 3 weeks decreased slightly.
CONCLUSIONThe blood coagulation function of guinea pigs exposed to 16 Hz/125 dB infrasound decreased, PT and INR may be used as the indexes to assess of blood coagulation function change induced by the infrasound exposure.