3D micro-CT analysis of void formations and push-out bonding strength of resin cements used for fiber post cementation.
- Author:
İsmail Hakkı UZUN
1
;
Meral Arslan MALKOÇ
;
Ali KELEŞ
;
Ayşe Tuba ÖĞRETEN
Author Information
- Publication Type:Original Article
- Keywords: Fiber post; Resin cement; Micro ct; Void formation; Push-out bonding
- MeSH: Cementation*; Dentin; Resin Cements*
- From:The Journal of Advanced Prosthodontics 2016;8(2):101-109
- CountryRepublic of Korea
- Language:English
- Abstract: PURPOSE: To investigate the void parameters within the resin cements used for fiber post cementation by micro-CT (µCT) and regional push-out bonding strength. MATERIALS AND METHODS: Twenty-one, single and round shaped roots were enlarged with a low-speed drill following by endodontic treatment. The roots were divided into three groups (n=7) and fiber posts were cemented with Maxcem Elite, Multilink N and Superbond C&B resin cements. Specimens were scanned using µCT scanner at resolution of 13.7 µm. The number, area, and volume of voids between dentin and post were evaluated. A method of analysis based on the post segmentation was used, and coronal, middle and apical thirds considered separately. After the µCT analysis, roots were embedded in epoxy resin and sectioned into 2 mm thick slices (63 sections in total). Push-out testing was performed with universal testing device at 0.5 mm/min cross-head speed. Data were analyzed with Kruskal–Wallis and Mann–Whitney U tests (α=.05). RESULTS: Overall, significant differences between the resin cements and the post level were observed in the void number, area, and volume (P<.05). Super-Bond C&B showed the most void formation (44.86 ± 22.71). Multilink N showed the least void surface (3.51 ± 2.24 mm2) and volume (0.01 ± 0.01 mm3). Regional push-out bond strength of the cements was not different (P>.05). CONCLUSION: µCT proved to be a powerful non-destructive 3D analysis tool for visualizing the void parameters. Multilink N had the lowest void parameters. When efficiency of all cements was evaluated, direct relationship between the post region and push-out bonding strength was not observed.