Quantitative evaluation of acute renal failure in rabbits with contrast-enhanced ultrasound.
- Author:
Yi DONG
1
;
Wen-ping WANG
;
Jia-ying CAO
;
Pei-li FAN
;
Xi-yuan LIN
Author Information
- Publication Type:Journal Article
- MeSH: Acute Kidney Injury; diagnostic imaging; Animals; Contrast Media; Rabbits; Ultrasonography
- From: Chinese Medical Journal 2012;125(4):652-656
- CountryChina
- Language:English
-
Abstract:
BACKGROUNDAssessment of perfusion in the early period of acute renal failure (ARF) is important, and can not be made by conventional ultrasound. The aim of this study was to prospectively test in a rabbit ARF model whether real-time contrast-enhanced ultrasound (CEUS) can quantitatively evaluate the hemodynamic changes of renal cortex in the early period.
METHODSThe model of ARF was induced in 30 healthy New Zealand white rabbits (2.5 - 3.0 kg), by intramuscular injection of 50% glycerin solution (12 ml/kg). CEUS were performed on right kidneys before, 6 and 24 hours after glycerin injection. CEUS quantitative indexes were measured in renal cortex using QLAB software. Comparisons between different stages were performed using paired t test. The sensitivity of CEUS in diagnosing ARF was compared with blood serum urea nitrogen (BUN), serum creatinine (SCr) level and color Doppler flow imaging (CDFI).
RESULTSAmong quantitative indexes, time to peak (TTP) and area under curve (AUC) increased significantly from (5.86 ± 2.57) seconds and (124.4 ± 46.7) dB·s before glycerin injection to (7.66 ± 2.05) seconds and (288.1 ± 64.9) dB·s 6 hours after injection (P < 0.05). Slope rate of ascending curve (A) and descending curve (a) decreased slightly from (3.00 ± 1.22) dB/s and (0.19 ± 0.15) 1/s to (2.80 ± 1.45) dB·s and (0.09 ± 0.02) 1/s (P < 0.05). Twenty-four hours later, only AUC increased significantly from (124.4 ± 46.7) dB·s to (466.2 ± 52.2) dB·s (P < 0.05).
CONCLUSIONQuantitative indexes of CEUS might be useful in predicting the hemodynamic changes of renal cortex in the early six hours of ARF model.