Abstract:
Objective To investigate the value of the Tinnitus Evaluation Questionnaire(TEQ) in clinical application.Methods Cronbach’s α coefficient was used to examine the reliability of the TEQ internal consistency.Examined the re-measured reliability by the correlation coefficient by two doctors’ 1-3 hours interval questionnaires’ scores.And inspected criteria validity according to the correlation coefficient of the TEQ and Tinnitus Handicap Inventory (THI).Results In the 202 tinnitus patients,the TEQ Cronbach’s α coefficient was 0.76 and re-measured reliability was 0.938.The THI correlation coefficient was 0.769.Among which,99 patients feel tinnitus alleviated obviously after the treatment,the TEQ scores were significantly lower than that before the treatment (t =21.42,P < 0.001 ).Conclusions The TEQ reflects the severity of tinnitus completely,and has preferable reliability and validity.The characteristics are concise,practical and exact.It is worthy of clinical application.