Simultaneous determination of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin in flowers of Pueraria lobata by HPLC.
- Author:
Lihui LIU
1
;
Weimin LI
;
Ying GAO
Author Information
- Publication Type:Journal Article
- MeSH: Chromatography, High Pressure Liquid; methods; Drugs, Chinese Herbal; analysis; Flowers; chemistry; Glucosides; analysis; Isoflavones; analysis; Pueraria; chemistry
- From: China Journal of Chinese Materia Medica 2010;35(17):2308-2311
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo develop a HPLC method for the simultaneous determination of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin in flowers of Pueraria lobata.
METHODThe separation was performed on a Kromasil C18 column (4.6 mm x 250 mm, 5 microm), using a gradient elution with acetonitrile-water containing 0.2% phosphoric acid as the mobile phase. The flow rate was 1.0 mL x min(-1), the detection wavelength was 265 nm and the temperature of column was 35 degrees C.
RESULTThe linear ranges of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin were 0.14-1.40 (r = 0.9994), 0.20-2.02 (r = 0.9993), and 0. 10-1.04 (r = 0.9991) , respectively. The average recoveries (n=6) of the three constituents were 99.5% (RSD 1.8%), 99.6% (RSD 1.7%), and 99.8% (RSD 1.9%), respectively.
CONCLUSIONThe method is simple and accurate with a good eata and can be used as a quality control method for flowers of P. lobata of different sources.