Dimensional accuracy of dental gypsum casts after immersion in stable chlorine dioxide disinfectant.
- Author:
Xiao-hong YANG
1
;
Guo-wei ZHU
;
Lin CHEN
Author Information
- Publication Type:Journal Article
- MeSH: Calcium Sulfate; Chlorine Compounds; pharmacology; Dental Impression Materials; Dental Models; Disinfectants; pharmacology; Disinfection; methods; Immersion; Oxides; pharmacology
- From: Journal of Zhejiang University. Medical sciences 2010;39(3):318-321
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo evaluate the changes in dimensional accuracy of dental gypsum casts after immersion in stable chlorine dioxide (SCD) disinfectant solution.
METHODSEach of 90 specimens was made of type III,type IV and type V dental stone, respectively,which were further divided into 9 groups (n=10). The gypsum casts were immersed in 3.71,7.41 and 11.12 mmol/L SCD disinfectant solution for 5, 10 and 15 min, respectively. The dimensional accuracy of dental gypsum casts were measured with outside diameter in micrometer before and after immersion. The data were analyzed using analysis of variance (ANVOA) at 95% confidence level.
RESULTThere were no significant changes in dimensional accuracy of all dental gypsum casts treated by same concentration of SCD solution for 5, 10 and 15 min. And the dimensional accuracy of all dental gypsum casts treated with different concentrations of SCD for the same duration did not change.
CONCLUSIONSCD disinfectant solution has no impact on dimensional stability of dental gypsum casts.