Influence of high-voltage electric burn on the microcirculation of heart in rabbit.
- Author:
Qing-fu ZHANG
1
;
Hui-min ZHOU
;
Che-jiang WANG
;
Hong-bo SHAO
Author Information
- Publication Type:Journal Article
- MeSH: Animals; Burns, Electric; physiopathology; Heart; physiopathology; Hemodynamics; Microcirculation; Rabbits
- From: Chinese Journal of Burns 2012;28(3):173-177
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo study the influence of high-voltage electric burn on the microcirculation of heart in rabbit.
METHODSOne-hundred and twenty New Zealand rabbits of clean grade were divided into control group (C) and electric burn group (EB) according to the random number table, with 60 rabbits in each group. Rabbits in EB group were subjected to high-voltage electric burn (the electrical current flow into the left foreleg at the lateral side of proximal end and out from the corresponding site of the right hind leg) with voltage regulator and experimental transformer. Rabbits in C group were sham injured with the same devices without electrification. At 15 minutes before injury, and 5 minutes, 1, 2, 4, 8 hour (s) post injury (PIM or PIH), ten rabbits in each group were chosen to examine the cardiac apex microcirculation hemoperfusion (CAMH) with laser Doppler hemoperfusion image instrument. The morphologic changes of microvessels of left ventricular wall tissues of 2 rabbits from each of the 10 rabbits collected at above-mentioned time points were observed with light microscope and transmission electron microscope. Auricular vein blood of rabbit was harvested at above-mentioned time points for the determination of aspartate amino transferase (AST), lactate dehydrogenase (LDH), hydroxybutyrate dehydrogenase (HBDH), creatine kinase (CK), and creatine kinase isozyme MB (CK-MB) by full-automatic biochemical analyzer. Data were processed with two-factor analysis of variance and LSD test.
RESULTS(1) The differences between C group and EB group in detection results were statistically significant, with F values from 425.991 to 3046.834, P values all below 0.01. Only the data within EB group were comparable. (2) At PIM 5, the CAMH value of rabbits in EB group was (1.96 ± 0.09) V, which was lower than that at 15 minutes before injury [(4.34 ± 0.35) V, P < 0.01]. The CAMH value of rabbits in EB group was increased at PIH 1 [(3.43 ± 0.30) V], and then it showed a tendency of decrease. (3) Bleeding and microthrombus formation were observed in venule and capillary vessel of rabbits in EB group at PIH 8. Breakage of basement membrane of capillary endothelial cells, mitochondrial swelling, and severe degranulation from damaged endoplasmic reticulum were observed in rabbits of EB group at PIH 8. (4) Levels of AST, LDH, HBDH, CK, and CK-MB in rabbits of EB group were significantly higher at PIH 1, 2, 4, 8 than at 15 minutes before injury (with P values all below 0.01). The AST level peaked at PIH 2 [(164 ± 39) U/L]. Levels of LDH and HBDH peaked at PIH 4, which were respectively (1016 ± 246) U/L and (487 ± 54) U/L. The CK level peaked at PIH 8 [(7799 ± 738) U/L]. The CK-MB level peaked at PIH 2 [(1848 ± 65) U/L].
CONCLUSIONSHigh-voltage electric burn can bring damage to the microvessels of heart in rabbits and change blood flow of microcirculation, which should be given adequate attention during the treatment.