Diagnostic value of contrast-enhanced ultrasound of thyroid nodules coexisting with Hashimoto's thyroiditis.
- Author:
Rui-na ZHAO
1
;
Bo ZHANG
1
;
Xiao YANG
1
;
Yu-xin JIANG
1
;
Xing-jian LAI
1
;
Shen-ling ZHU
1
;
Xiao-yan ZHANG
1
Author Information
- Publication Type:Journal Article
- MeSH: Contrast Media; Hashimoto Disease; Humans; Thyroid Nodule; diagnostic imaging; Ultrasonography
- From: Acta Academiae Medicinae Sinicae 2015;37(1):66-70
- CountryChina
- Language:English
-
Abstract:
OBJECTIVETo evaluate the value of contrast-enhanced ultrasound (CEUS) in diagnosing thyroid nodules coexisting with Hashimoto's thyroiditis (HT).
METHODSTotally 62 thyroid nodules in 48 HT patients were retrospectively analyzed. The CEUS characteristics were reviewed, and diagnostic value of enhancement pattern and peak intensity were calculated.
RESULTSPeak intensity (P=0.002) and enhancement pattern (P<0.001) differed significantly between malignant and benign thyroid nodules. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of heterogeneous enhancement were 97.6%, 85.7%, 93.0%, 94.7%, and 93.5%, respectively. Sensitivity, specificity, PPV, NPV and accuracy of low intensity at peak time were 85.4%, 52.4%, 77.8%, 64.7%, and 74.2%, respectively.