Retrospective study of combined application of interspinous process fixation system and rigid fixation system for degenerative lumbar diseases.
- Author:
Hao-lin SUN
1
;
Chun-de LI
;
Xian-yi LIU
;
Hong LI
;
Zheng-rong YU
;
Jing-rong LIN
;
Xiao-dong YI
;
Hong LIU
;
Hai-lin LU
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Aged; Female; Follow-Up Studies; Humans; Internal Fixators; Lumbar Vertebrae; surgery; Male; Middle Aged; Retrospective Studies; Spinal Diseases; surgery; Spinal Fusion; methods; Treatment Outcome
- From: Chinese Journal of Surgery 2010;48(5):363-367
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo assess the efficacy and safety of combined application of interspinous process fixation system and rigid fixation system for degenerative lumbar diseases.
METHODSFrom September 2007 to September 2008, 16 cases with degenerative lumbar diseases were treated with combined application of interspinous process fixation system and rigid fixation system. The clinical results were assessed by VAS of pain of lumbar and lower limbs, lumbar JOA score and Prolo functional score. The radiological results including implant position (interspinous process, pedicle screws and plates), spinous process fracture, segmental range of motion (the non-fusion fixation segment, and the intermediate segments between fused and non-fused segments) which were assessed by lumbar static and dynamic X rays.
RESULTSAll 16 cases obtained an average follow-up of 17.6 months. At final follow up, lumbar VAS, lower limbers VAS, lumbar JOA score and Prolo functional score were significant improved than those of pre-operation (lumbar VAS: 1.9 +/- 1.4 vs. 4.5 +/- 3.1; lower limbs VAS: 1.7 +/- 1.2 vs. 6.3 +/- 2.9; lumbar JOA score: 22.8 +/- 3.3 vs. 12.5 +/- 4.7; Prolo functional score: 8.3 +/- 1.2 vs. 4.0 +/- 2.3). Range of motion of the non-fusion fixation segment was (9.8 +/- 4.2) degrees and that of the intermediate segments between fused and non-fused segments was (13.2 +/- 3.5) degrees .
CONCLUSIONSCombined application of interspinous process fixation system and rigid fixation system for degenerative lumbar diseases provides a new idea to avoid the multi-segment fusion fixation and pertinent potential problems. Short-term clinical results are successful.