Evaluation of a heart-type fatty acid-binding protein detection kit for diagnosis of acute coronary syndrome.
- Author:
Yawei LIU
1
;
Miao TIAN
;
Xinzhi JIANG
;
Jiakun LUO
;
Zhiyong YI
Author Information
- Publication Type:Journal Article
- MeSH: Acute Coronary Syndrome; diagnosis; Biomarkers; blood; Enzyme-Linked Immunosorbent Assay; Fatty Acid Binding Protein 3; Fatty Acid-Binding Proteins; blood; Humans; Reagent Kits, Diagnostic; Reproducibility of Results; Sensitivity and Specificity
- From: Journal of Southern Medical University 2014;34(6):901-903
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo evaluation the performance of a heart-type fatty acid-binding protein (H-FABP) ELISA detection kit in the clinical diagnosis of acute coronary syndrome (ACS).
METHODSPlasma or serum samples from 160 suspected ACS patients hospitalized in General Hospital of PLA were examined using Lanzhou H-FABP reagent kit and Holland H-FABP kit. Correlation of the two kits was evaluated and Kappa test was used to examine the consistency of the results of the two products.
RESULTSThe sensitivity of H-FABP diagnosis of ACS detection Lanzhou kit was 91.8%, the specificity was 88.7%, and the total diagnostic rate was 90.42%. The sensitivity of H-FABP diagnosis of ACS detection Holland kit was 90.3%, the specificity was 86.8%, and the total diagnostic rate was 88.75%. The test results showed that two products yielded comparable results (P=0.668, >0.05) with a good consistency (Kappa=0.726, P<0.01).
CONCLUSIONSH-FABP ELISA detection kit produccted by LanZhou biological research institute has a good correlation with H-FABP detection kit produced by HBT company of Holland and has the potential for clinical application.