The experimental research of the influence of cervical settling method on marginal accuracy of wax patter.
- Author:
Wei-shan DING
1
;
Ai-ling HUANG
;
Yi-jun HU
;
Zhao-xia DU
;
Duo WANG
Author Information
- Publication Type:Journal Article
- MeSH: Dental Casting Technique; Dental Marginal Adaptation
- From: West China Journal of Stomatology 2010;28(2):174-176
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo study the influence of cervical settling method on marginal accuracy of wax patters.
METHODS24 wax patterns were made on the standard cast specimens and round capsules of which twelve patters were made with the method of cervical settling (experiment group), twelve patters were made with the method of wax dripping (control group). Marginal accuracy of patterns were measured before sublation, sublation half an hour and twenty-four hours.
RESULTSThe results revealed that marginal accuracy had significant difference between the cervical settling methods and wax dripping methods (P < 0.05). There was significant difference between the cervical settling methods measured after half an hour and twenty-four hours (P < 0.01). There was also significant difference between the wax dripping methods measured after half an hour and twenty-four hours (P < 0.01).
CONCLUSIONWax patterns with the method of cervical settling can improve marginal accuracy of patterns. The marginal accuracy of wax patters are influenced by the existing time.