Preliminary analysis about influence of porcelain thickness on interfacial crack of PFM.
- Author:
Ziyuan ZHU
1
;
Baowei ZHANG
;
Xiuyin ZHANG
;
Kan XU
;
Ruhua FANG
;
Dongmei WANG
Author Information
- Publication Type:Journal Article
- MeSH: Dental Porcelain; Dental Stress Analysis; Humans
- From: Chinese Journal of Stomatology 2002;37(1):21-23
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVEThis study was about the influence of porcelain thickness on crack at interface.
METHODSThe effect of porcelain thickness on the flaw at the interface between porcelain and metal was studied in three groups with porcelain thickness of 0.5 mm, 1.5 mm and 2.5 mm (metal thickness of 0.5 mm) by means of moire interferometre and interfacial fracture mechanics. The parameter Jc was compared among the three groups and the growing of the flaw was observed.
RESULTSJc and the extreme strength of group with porcelain thickness of 0.5 mm (2.813 N/m and 9.979 N) were lower than those of the groups with porcelain thickness of 1.5 mm and 2.5 mm (5.395 N/m, 19.134 N and 5.429 N/m, 19.256 N). Flaws extend along the interface in the groups with porcelain thickness of 1.5 mm and 0.5 mm.
CONCLUSIONS(1) Fracture resistance of the interface in the groups with porcelain thickness of 1.5 mm and 2.5 mm is similar and it decreases in the group with 0.5 mm thick porcelain. (2) When porcelain is 1.5 mm or 0.5 mm thick, flaws will extend along the interface. When porcelain is 2.5 mm thick, flaws will extend into the porcelain layer.