Redo coronary artery bypass grafting: on-pump and off-pump coronary artery bypass grafting revascularization techniques.
- Author:
Song WU
1
;
Feng WAN
1
;
Zhe ZHANG
1
;
Hong ZHAO
1
;
Zhong-qi CUI
1
;
Ji-yan XIE
1
Author Information
- Publication Type:Journal Article
- MeSH: Aged; Coronary Artery Bypass; methods; Coronary Artery Disease; surgery; Female; Humans; Male; Middle Aged; Reoperation
- From: Chinese Medical Sciences Journal 2015;30(1):28-33
- CountryChina
- Language:English
-
Abstract:
OBJECTIVETo analyze the short-term outcomes of redo coronary artery bypass grafting (CABG) using on-pump and off-pump CABG techniques.
METHODSFrom January 2003 to August 2013, non-randomized 80 patients were treated with redo CABG in the Department of Cardiac Surgery, Peking University Third Hospital. Among these patients, 40 underwent on-pump CABG technique (redo-ONCAB group) and 40 underwent off-pump CABG technique (redo-OPCAB group). Furthermore, transmyocardial laser revascularization was performed in high-risk patients who were not suitable to conventional grafting. Clinical data of the two groups were recorded and analyzed including operation time, coronary grafts, incomplete revascularization, postoperative ventilation, perioperative stroke, and low output syndrome, etc.
RESULTSThere were no significantly differences in age, gender distribution, incidences of hypertension, stroke, and other clinical characteristics between redo-OPCAB group and redo-ONCAB group (all P>0.05), except for incidences of renal dysfunction and pulmonary disease (all P<0.05). The number of grafting vessels in the redo-ONCAB and redo-OPCAB groups was 2.1 ± 0.74 and 1.4 ±0.52 respectively. There was significant difference between the two groups (P=0.0243). Compared with the redo-ONCAB group, there was shorter operation time (P=0.0045), postoperative ventilation (P=0.0211) and intensive care unit stay (P=0.0400), as well as fewer use of platelet (P=0.0338) and blood transfusion (P=0.0034) in the redo-OPCAB group. The incidence of incomplete revascularization (P=0.0253) and the use of transmyocardial laser revascularization (P=0.0052) were higher in the redo-OPCAB group than those in the redo-ONCAB group (all P<0.05). However, no significant differences were showed for the incidence of the use of intra aortic balloon pump and continuous renal replacement therapy, perioperative stroke, low output syndrome, and in-hospital mortality between the two groups (all P>0.05).
CONCLUSIONRedo CABG is the safety and efficacy surgical procedure, and redo-OPCAB technique with better outcomes is commended especially in high-risk patients.