The efficacy of two type of membrane plasma separator on the treatment of patients with chronic severe hepatitis B.
- Author:
Da-zhi ZHANG
1
;
You-rong ZHAO
;
Quan-hai ZHANG
;
Zhi-yi WANG
;
Bo QIN
;
Hua HE
;
Zhi ZHOU
;
Shu-hua GUO
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Aged; Bilirubin; blood; Female; Hepatitis B, Chronic; therapy; Humans; Male; Middle Aged; Plasma Exchange; instrumentation
- From: Chinese Journal of Hepatology 2004;12(4):208-209
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVEIn order to compare the efficacy of two kinds of membrane plasma separator on the treatment of patients with severe hepatitis B.
METHODS63 cases suffering from chronic severe hepatitis B were divided into two groups, 25 cases were treated with plasma exchange using Evacure-4A membrane plasma separator (A group) or 38 cases were using PS-06 membrane plasma separator (B group). Both of them also were treated with similar basic medical treatment. The level of serum total bilirubin, non-conjugated bilirubin, prothrombin time and albumin were tested at baseline and the end of the treatment with PE.
RESULTSEvacure-4A and PS-06 membrane plasma separators can effientively remove bilirubin, the levels of serum total bilirubin, non-conjugated bilirubin of all patients were significantly decreased after treated with PE. In A group, the level of serum total bilirubin, non-conjugated bilirubin decreased from (464.2+/-193.8)micromol/L to (279.4+/-158.7)micromol/L, (293.5+/-129.1)micromol/L to (175.5+/-106.7)micromol/L (t=5.45, 10.36, P<0.01) respectively. In B group, the level of serum total bilirubin, non-conjugated bilirubin decreased from (493.2+/-126.9)micromol/L to (299.7+/-96.5)micromol/L, (300.2+/-74.3)micromol/L to (171.5+/-53.1)micromol/L (t=5.17, 12.04, P<0.01) respectively. The level of serum albumin increased after treated with PE in A and B groups, to contrast with PS-06, the increasing percentage of albumin was higher when the patients were treated with PE using Evacure-4A membrane plasma separator [(8.3+/-0.7) % vs. (3.4+/-9.3) %, t = 2.76, P<0.01].
CONCLUSIONEvacure-4A membrane plasma separator may be better than PS-06 membrane plasma separator on the treatment of patients with chronic severe hepatitis B.