Simultaneous determination of the four effective components in Huaijiao pill by HPLC.
- Author:
Qing-Quan BIAN
1
;
Zhen-Ping YANG
;
Jia-Qin LIU
;
Si-Man LIU
Author Information
- Publication Type:Journal Article
- MeSH: Chromatography, High Pressure Liquid; methods; Drug Combinations; Drugs, Chinese Herbal; chemistry; isolation & purification; Genistein; analysis; Isoflavones; analysis; Plants, Medicinal; chemistry; Quercetin; analysis; Reproducibility of Results; Rutin; analysis; Sophora; chemistry
- From: China Journal of Chinese Materia Medica 2005;30(19):1513-1515
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo develop an HPLC method for determination of the four effective components (genistin; rutin; quercetin; genistein) in Huaijiao pill.
METHODThe chromatographic separation was performed on a Shim-packODS (4.6 mm x 150 mm, 5.0 microm) eluted with a mobile phase of MeOH-H2O-HAc (40:60:0.25). The detection wavelength was set at 256 nm and column temperature was set at 30 degrees C .
RESULTNice linear relation between the peak area and injected amount exists when the amount is within 0.059-0.352 microg for genistin, within 0.435-2.610 microg for rutin, within 0.020-0.121 microg for quercetin and within 0.053-0.319 microg for genistein. The correlation coefficient of each component is 0.999 6, 0.998 2, 0.998 9 and 0.999 9 respectively. The average recoveries of the four components are from 98.7% to 100.2%. The RSD of each group are 1.21%, 1.36%, 0.47% and 1.54% (n = 5).