Minimally invasive osteosynthesis of distal tibial fractures using anterolateral locking plate: Evaluation of results and complications.
- Author:
Devendra LAKHOTIA
1
;
Gaurav SHARMA
;
Kavin KHATRI
;
G-N KUMAR
;
Vijay SHARMA
;
Kamran FAROOQUE
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Aged; Bone Plates; Female; Fracture Fixation, Internal; adverse effects; methods; Humans; Male; Middle Aged; Minimally Invasive Surgical Procedures; adverse effects; methods; Tibial Fractures; surgery
- From: Chinese Journal of Traumatology 2016;19(1):39-44
- CountryChina
- Language:English
-
Abstract:
PURPOSESoft tissue healing is of paramount importance in distal tibial fractures for a successful outcome. There is an increasing trend of using anterolateral plate due to an adequate soft tissue cover on ante- rolateral distal tibia. The aim of this study was to evaluate the results and complications of minimally invasive anterolateral locking plate in distal tibial fractures.
METHODSThis is a retrospective study of 42 patients with distal tibial fractures treated with minimally invasive anterolateral tibial plating. This study evaluates the bone and soft tissue healing along with emphasis on complications related to bone and soft tissue healing.
RESULTSFull weight bearing was allowed in mean time period of 4.95 months (3-12 months). A major local complication of a wound which required revision surgery was seen in one case. Minor complications were identified in 9 cases which comprised 4 cases of marginal necrosis of the surgical wound, 1 case of superficial infection, 1 case of sensory disturbance over the anterolateral foot, 1 case of muscle hernia and 2 cases of delayed union. Mean distance between the posterolateral and anterolateral incision was 5.7 cm (4.5-8 cm).
CONCLUSIONThe minimally invasive distal tibial fixation with anterolateral plating is a safe method of stabilization. Distance between anterolateral and posterolateral incision can be placed less than 7 cm apart depending on fracture pattern with proper surgical timing and technique.