Comparison of the shaping capability of reciprocating instruments in simulated canals in vitro.
- Author:
Tongfei SHAO
;
Xiaomei HOU
;
Benxiang HOU
- Publication Type:Journal Article
- MeSH: Dental Pulp Cavity; Humans; In Vitro Techniques; Nickel; Root Canal Preparation; Titanium
- From: West China Journal of Stomatology 2014;32(6):606-610
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVEThis study aims to evaluate the shaping capability of Reciproc, WaveOne, Mtwo, and ProTaper instruments in simulated root canals.
METHODSA total of 40 simulated resin blocks were divided randomly into four groups. Each group was prepared with Reciproc (Group 1), WaveOne (Group 2), Mtwo (Group 3), and ProTaper (Group 4). The preparation time and reduction in working length after preparation were measured. Pre- and post-operative images were obtained with a scanner and superimposed through Photoshop. The changes in canal curvature and material removal from the inner and outer canal walls at 10 points beginning at 1 mm from the end point of the canal were measured with Image J. Centering capability was determined accordingly. Data were analyzed through one-way ANOVA, SNK, and Kruskal-Wallis at a significance level of P < 0.05.
RESULTSThe preparation time of Group 2 was (53.7 ± 6.7) s, whereas those of Groups 1, 3, and 4 were (86.9 ± 8.1) s, (112.2 ± 8.2) s, and (177.9 ± 11.2) s, respectively; the difference was found to be significant (P < 0.05). The reductions in working length among the four groups after preparation were not significantly different (P > 0.05). The canal curvature for Groups 1 to 4 were 2.671° ± 0.637°, 2.667° ± 0.450°, 3.664° ± 0.870°, and 3.797° ± 0.601°, respectively. The changes for Groups 1 and 2 were significantly smaller than those for Groups 3 and 4. At the 3 mm point, the transportation of Group 1 was (-0.016 ± 0.094) mm, which was significantly less than that of the other instruments (P<0.05). At the 4 mm and 5 mm points, the trans- portation values of Group 2 were (-0.080 ± 0.104) mm and (-0.312 ± 0.088) mm, which were significantly less than that of Group 1 [(-0.243 ± 0.099) mm, (-0.404 ± 0.064) mm, P < 0.05].
CONCLUSIONReciproc and WaveOne can complete preparation faster and can maintain the original canal curvature better than Mtwo and ProTaper. Reciproc exhibits superior centering capability in the apical part of the canal, whereas WaveOne exhibits superior centering capability in the middle part of the canal.