Changes in Anterior Chamber Depth and Refraction after Accommodative Intraocular Lens Implantation.
10.3341/jkos.2007.48.11.1479
- Author:
Jae Hui KIM
1
;
Chun Sung PARK
;
Eui Sang CHUNG
;
Tae Young CHUNG
Author Information
1. Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. tychung@smc.samsung.co.kr
- Publication Type:Original Article
- Keywords:
Accommodative IOL;
Anterior chamber depth;
AT-45;
Crystalens;
Refraction
- MeSH:
Anterior Chamber*;
Humans;
Lens Implantation, Intraocular*;
Lenses, Intraocular*;
Phacoemulsification;
Prospective Studies;
Refractive Errors
- From:Journal of the Korean Ophthalmological Society
2007;48(11):1479-1486
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
PURPOSE: To evaluate the change in anterior chamber depth and refraction after AT-45 implantation METHODS: Twenty-two eyes from 22 patients were enrolled in this prospective study. After phacoemulsification, AT-45 (11 eyes) and SA60AT (11 eyes) were implanted. Clinical data included anterior chamber depth and refractive error at 1 week, 1 month, 2 months and 6 months postoperatively. The correlation between anterior chamber depth change and spherical equivalent change was also evaluated. RESULTS: In the AT-45 implanted group, the mean anterior chamber depth was 4.56+/-0.59 mm at 1 week postoperative, 4.70+/-0.69 mm at 1 month postoperative, 4.78+/-0.71 mm at 2 months postoperative and 4.76+/-0.69 mm at 6 months postoperative. The mean spherical equivalent was -0.53+/-0.48D, -0.37+/-0.42D, -0.27+/-0.47D, and -0.33+/-0.44D respectively. When analyzed using the Mann-Whitney U test, p-values of anterior chamber depth differences between the 2 groups were P=0.52 at 1 week to 1 month, P=0.32 at 1 month to 2 months, P=0.89 at 2 months to 6 months, and P=0.02 at 1 week to 6 months, showing a deeper anterior chamber in the AT-45 implanted group. P-values (Mann-Whitney U test) of spherical equivalent differences between the 2 groups were P=0.33, P=0.56, P=0.94, and P=0.19, respectively, showing more hyperopic change in the AT-45 implanted group. The correlation between anterior chamber depth change and spherical equivalent change in the AT-45 implanted group at 1 week to 6 months was not statistically significant (Spearman correlation analysis, P=0.223). CONCLUSIONS: Anterior chamber depth deepening and associated hyperopic refractive change were observed after AT-45 implantation, especially at 1 month after the surgery.