Comparison of Maximal Removal Rate of Indocyanine Green and Monoethylglycinexylidide Test in Quantitative Assessment of Hepatic Function.
- Author:
Gyeong Seon KIM
;
Chun Hee LEE
;
Young Sook KIM
;
Yong Ung LEE
;
Sung Hye SHIN
;
Dong Guen LEE
- Publication Type:Original Article
- MeSH:
Adult;
Chromatography, High Pressure Liquid;
Chromatography, Liquid;
Female;
Fluorescence Polarization Immunoassay;
Healthy Volunteers;
Humans;
Indocyanine Green*;
Lidocaine;
Liver Diseases;
Male;
Mesons;
Metabolism
- From:Korean Journal of Clinical Pathology
1997;17(6):956-967
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
BACKGROUND: The maximal removal rate of indocyanine green (ICG Rmax), which has been used as a useful indicator of quantitative assessment of the hepatic function, has some disadvantages such as high cost, requirement of multiple sampling, and long turn-around time. This study was designed to clarify that the measurement of the lidocaine metabolite, monoethylglycinekylidide (MEGX) test, can replace the ICG Rmax. And in healthy adults, MEGX forma pion was measured and compared according to methods of measurement and serf. METHOD: In 18 patients to whom ICG Rmax test was requested, ICG Rmax test was carried out at two doses of 0.5 mg/kg and 5 mg/kg and MEGX formation after 15 minute of 1 mg/kg lidocaine Injection was measured by fluorescence polarization immunoassay (FPIA) method. The correlation between them was analyzed, To 25 healthy volunteers included in this study as normal control, lidocaine was given intravenously at, a dose of 1 mg/kg and MEGX forma pion was measured IS and 30 minute later (MEGX15, MEGX30) using both high performance liquid chromatography (HPLC) and FPIA methods. RESULT: Patient group resealed significant correlation between ICG Rmax and MEGX15 (r=0.7674, p<0.001) and also between ICG Rl5 and MEGX15 (r=0.5612, p=0.008). There was significant difference between MEGX15 of 9 patients with chronic liver diseases and those of normal controls (22.24+/- 13.18 and 35.40+/- 14.43 ng/mL, respectively) (p=0.01). In normal controls, the correlation between methods was significant (p=0.001) and the values measured by FPIA method was significantly higher than that by HPLG (p(0.001). Of the normal controls, male group had higher MEGX15 values than female group in both methods (in HPLC method 33.89+/-15.95 and 22.53+/- 8.36, and in FPIA method 41.48+/-16.61 and 28.81+/-7.88 ng/mL, respectively), and in female group MEGX30 values was significantly elevated compared to MEGX15 (p<0.001). CONCLUSION: Inferred from the fact that the correlation between ICG Rmax and MEGX was good, MEGX test can be considered a replacement for ICG Rmax. In healthy adults, it is considered that there is serf-related difference In the rate of lidocaine metabolism so we should pay attention to it in interpreting the MEGX results.