An Experiment on Intraoperative Autotransgusion and Normovolemic Hemodilution with hartmann`s Solution and Rheomacrodex .
10.4097/kjae.1978.11.2.97
- Author:
Kwang Woo KIM
1
;
Dong Soo KIM
;
Sung Duck KIM
;
Kun il LEE
Author Information
1. Department of Anesthesiology, College of Medicine, Seoul National University, Seoul, Korea.
- Publication Type:Original Article
- MeSH:
Blood Transfusion, Autologous;
Central Venous Pressure;
Dextrans*;
Heart Rate;
Hematocrit;
Hemodilution*;
Oxygen;
Radial Artery
- From:Korean Journal of Anesthesiology
1978;11(2):97-101
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
We had recently 10 cases of intraoperative autotransfusion with arterial blood and concomitantly normovolemic hemodilution with Hartmanns solution and Rheomacrodex which amount 6 d to half the removal of arterial blood through a cannulated radial artery. We observed mean arterial pure, heart rate, central venous pressure, hematocrit and arteriovenous oxygen content difference compared to controls, just after removal of arterial blood with concomitant hemodilution and after autotransfusion. There were no changes of the above observations except for hematocrit values during the experiment. We recommend intraoperative autotransfusion with arterial blood and normovolemic hemodilution as a safe technique.