A STUDY OF IMPRESSION TECHNIQUE USING PUTTY MATERIAL OF PVS IMPRESSION MATERIAL.
- Author:
Young Chan JEON
1
;
Kyung soo NAH
Author Information
1. College og Dentistry, Pusan National University, Dept. of Prosthodontics, Korea.
- Publication Type:Original Article
- MeSH:
Gingiva;
Silicones;
Tooth;
Viscosity
- From:The Journal of Korean Academy of Prosthodontics
1997;35(3):535-543
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
In order to compare the accuracy of impression technique using the addition silicone putty and improved heavy body material, impression were taken for the natural 6 maxillary anterior teeth, and for the metal mast model that has full arch shape with 4 cylindrical abutment teeth, Marginal gingiva was retracted by routine method using retraction cord, and two techniques were tried to compare the length of impression materials in the gingival sulcus. This was aimed to see the effect of viscosity and hydraulic pressure of impression materials for the subgingival impression. Impressions for the full arch-shaped metal master model were taken to compare the linear stability of the different impression materials and their related techniques. The conclusions were as belows : 1. The one-step impression technique showed longer extension of impression material in gingival sulcus than two-step impression technique. 2. High viscosity and hydraulic pressure of impression material were useful to take subgingival impression. 3. There was no statistically significant difference for the two-dimensional accuracy of impression technique, but two-step technique showed better trend than one-step technique.