Experimental Strebismus Surgery with Tissel in Rabbit Models.
- Author:
Gong Ja SEONG
1
;
Hong Bok KIM
;
Hyoung Jun KOH
Author Information
1. Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
- Publication Type:Original Article
- Keywords:
strabismus surgery;
tensile strength;
Tisseeling
- MeSH:
Fibrin Tissue Adhesive*;
Polyglactin 910;
Rabbits;
Strabismus;
Suture Techniques;
Tensile Strength
- From:Journal of the Korean Ophthalmological Society
1991;32(1):83-88
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
We performed experimental surgery with Tisseel in rabbit models, to determine whether Tisseeling can replace the classic suture technique. 30 albino rabbits were divided into two groups-one group was Tisseel group(15 rabbits) and the other was Vicryl group(15 rabbits). The superior rectus and inferior rectus were recessed and resected 5mm. Both groups were killed 2,4, and 6 weeks after the surgery respectively and the eyes were enucleated. The tensile strength and pathological findings were compared between the two groups. From this study, we found that Tisseeling had good tensile strength and minimal tissue reaction. Thus Tisseeling is considered to be good method in strabismus surgery.