Histological Quality of Small Polyps Resected Uoosing Different Electric Currents in a Colonoscopic Polypectomy.
- Author:
Si Hyung LEE
1
;
Byung Ik JANG
;
Tae Nyeun KIM
;
Joon Hyuk CHOI
Author Information
1. Department of Internal Medicine, Yeungnam University College of Medicine, Daegu, Korea. jbi@med.yu.ac.kr
- Publication Type:Original Article
- Keywords:
Endocut;
Blended cut;
Colonoscopic polypectomy
- MeSH:
Cautery;
Humans;
Mucous Membrane;
Polyps;
SNARE Proteins
- From:Korean Journal of Gastrointestinal Endoscopy
2008;37(3):174-178
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
BACKGROUND/AIMS: Most polyps encountered during a colonoscopic polypectomy are small. Thus, accurate evaluation of small polyp histology is important in the decision-making process. The aim of this study was to assess and compare the histological quality of polyps obtained by the use of snare polypectomy with two different electric currents. METHODS: Consecutive polyps less than 1 cm were identified and removed by use of either the blend mode (Blended mode, Circon, BC-200) or automatic cutting and coagulation mode (Endocut Q mode, effect 3, 40 watts, ERBE, VAIO-300). An experienced gastrointestinal pathologist evaluated the specimens for cautery damage, margin, architecture, presence of muscularis mucosa and general histological quality. RESULTS: Sixty-six patients (77.2% men; mean age, 60.2+/-9.2 years) underwent 109 polypectomies (53 using the blended mode and 56 using the Endocut Q mode; mean polyp diameter, 0.87+/-0.17 mm). Age, gender, location, diameter and the histology of the polyp was not different with the use of both methods. The cautery amount (> or =2) with use of the blended mode was not significantly different than with the use of the Endocut mode (50.9% vs. 39.2%, p=0.22). The cautery degree, margin, architecture, presence of muscular mucosa and overall histological quality was not different with the use of both methods. CONCLUSIONS: The histological quality of polyps less than 1 cm obtained by use of either the blended mode or Endocut Q mode was not different.