- Author:
Ha Young KIM
1
;
Ryan Jin KIM
;
Sarah QADEER
;
Chang Mo JEONG
;
Sang Wan SHIN
;
Jung Bo HUH
Author Information
- Publication Type:Case Report
- Keywords: Immediate Loading; Dental Implant; Overdenture; SFI-bar
- MeSH: Aged; Dental Implants; Denture, Overlay; Dentures; Female; Humans; Mandible; Retention (Psychology)
- From:The Journal of Advanced Prosthodontics 2011;3(1):47-50
- CountryRepublic of Korea
- Language:English
- Abstract: Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar(R) (Cendres et Metaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.