The Evaluation of Minnesota Code in Electrocardioraphic Diagnosis of Ventricular Hypertrophy.
10.4070/kcj.1977.7.2.61
- Author:
Hee Sung SONG
;
Chi Ho CHOI
;
Young Moo RO
;
Soon Kyu SUH
;
Hong Chae PARK
;
Kyong Won LEE
- Publication Type:Original Article
- MeSH:
Diagnosis*;
Electrocardiography;
Hypertrophy*;
Hypertrophy, Left Ventricular;
Hypertrophy, Right Ventricular;
Minnesota*
- From:Korean Circulation Journal
1977;7(2):61-65
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Authors evaluated the electrocardiographic criteria of Minnesota Code (III-1, III-2) for the diagnosis of left and right ventricular hypertrophy in 93 cases of healthy peoples, 74 cases of left ventricular hypertrophy and 4 cases of right ventricular hypertrophy and following results were obtained. 1. By left ventricular hypertropy criteria (III-1), there were 5.4% of false positive and 14.9% of false negative cases. 2. By right ventricular hypertrophy criteria III-2), there were 24.7% of false positive and 20.0% of false negative cases. 3. Electrocardiographic diagnosis of ventricular hypertrophy by Minnesota Code (III-1, III-2) were more reliable criteria than many other criteria of ventricular hypertrophy.