The Treatment of Giant Middle Artery Aneurysm with MDS Coil: Case Report.
10.12701/yujm.1997.14.1.237
- Author:
Gwang Shik CHOI
1
;
Sung Ho KIM
;
Jung Ho BAE
;
O Lyong KIM
;
Byung Youn CHOI
;
Soo Ho CHO
;
Woo Mok BYUN
Author Information
1. Department of Neurosurgery College of Medicine, Yeungnam University Taegu, Korea.
- Publication Type:Case Report
- Keywords:
Giant aneurysm;
Endovascular treatment;
MDS-coil;
Intraluminal thrombus
- From:Yeungnam University Journal of Medicine
1997;14(1):237-244
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
A 14-year old boy was admitted with stuporous mentality. CT scan, MRI and cerebral angiogram revealed SAH and a giant aneurysm of right middle cerebral artery(4x5x5.3cm). To minimize surgical risk, endovascular treatment was done with MDS(mechanical detachable system)-spiral coil. Follow up MRI showed intraluminal thrombus formation of the aneurysm.