Clinical Studies on Electro-Oculography: Quantitative analysis of Smooth pursuit, OKN, and Bithermal Caloric test.
- Author:
Seung Hyun KIM
1
;
Hong Ki SONG
;
Byung Chul LEE
;
Hyung Jong KIM
;
Ki Bum SUNG
;
Ju Han KIM
;
Myung Ho KIM
;
Kyung Cheon CHUNG
;
Kwang Woo LEE
Author Information
1. Department Neurology, Hallym University.
- Publication Type:Original Article
- MeSH:
Caloric Tests*;
Electrooculography;
Eye Movements;
Nystagmus, Pathologic;
Ocular Motility Disorders;
Pursuit, Smooth*;
Reference Values;
Reflex
- From:Journal of the Korean Neurological Association
1992;10(2):188-196
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Electrooculography (EOG or ENG) is the simplest and most readily available diagnostic tool for recording and quantitatively analysing the pathologic nystagmus, visually guided eye movements (saccades, pursuits, OKN) and Vestibular-ocular reflexes. By using our standard method, we analyzed the normal ranges of smooth pursuit velocity and its gain, slow component velocity of OKN, and the bitherrnal caloric response. Our results of ENG tests for normal controls would be used as a basic quantitative data in evaluating vestibular dysfunction, and ocular motility disorders.