A comparison of hemodynamic changes after endotracheal intubation by the Optiscope(TM) and the conventional laryngoscope.
10.4097/kjae.2012.63.2.130
- Author:
Duk Dong KO
1
;
Hyun KANG
;
So Young YANG
;
Hwa Yong SHIN
;
Chong Wha BAEK
;
Yong Hun JUNG
;
Young Cheol WOO
;
Jin Yun KIM
;
Gill Hoi KOO
;
Seong Deok KIM
Author Information
1. Department of Anesthesiology and Pain Medicine, College of Medicine, Chung-Ang University, Seoul, Korea. roman00@naver.com
- Publication Type:Original Article ; Randomized Controlled Trial
- Keywords:
Bronchoscopes;
Endotracheal intubation;
Fiberoptics;
Hemodynamics;
Laryngoscope;
Video recording
- MeSH:
Adult;
Anesthesia, General;
Arterial Pressure;
Blood Pressure;
Bronchoscopes;
Heart Rate;
Hemodynamics;
Humans;
Incidence;
Intubation;
Intubation, Intratracheal;
Laryngoscopes;
Pharyngitis;
Video Recording;
Vocal Cords
- From:Korean Journal of Anesthesiology
2012;63(2):130-135
- CountryRepublic of Korea
- Language:English
-
Abstract:
BACKGROUND: Optiscope(TM) is a newly developed video stylet device. This study evaluated and compared the hemodynamic changes observed after endotracheal intubation with video stylet and after conventional laryngoscopic endotracheal intubation. METHODS: Fifty-eight adult patients with American Society of Anesthesiologists (ASA) physical status class 1 or 2, undergoing general anesthesia, were randomized into two groups: one group of patients were intubated using video stylet (n = 29) and the other group were intubated using direct laryngoscope (n = 29). Systolic blood pressure (SBP), mean arterial pressure (MAP), diastolic blood pressure (DBP), heart rate (HR), POGO (percentage of glottic opening) score, time for intubation and degree of sore throat were recorded. RESULTS: There were no significant differences in the SBP, MAP, DBP, HR, and the sore throat incidence between the two groups. Optiscope(TM) produced better POGO scores, but time for intubation was longer than with conventional laryngoscope. CONCLUSIONS: Optiscope(TM), when compared with conventional laryngoscope for intubation, does not modify the hemodynamic response, but it provides a better view of the vocal cords.