Assessment of IgE Detecting Methods in Cord and Maternal Serum.
- Author:
Chun Wook PARK
;
Jong Yuk YI
;
Hyung Ok KIM
;
Chung Won KIM
- Publication Type:Original Article
- Keywords:
Cord IgE;
Overnight PRIST using RAST anti - IgE tracer
- MeSH:
Immunoglobulin E*
- From:Korean Journal of Dermatology
1986;24(2):219-224
- CountryRepublic of Korea
- Language:English
-
Abstract:
The aim of the present work is to evaluate the most accurate technique for analysirig low levels of serum IgE. Following results are obtained from experiments by PRIST, Overnight PRIST, PRIST using RAST anti-IgE tracer and Overnight PRIST using RAST anti-IgE tracer methods with cord serum and maternal serum of 21 individuals respectively. 1) There was no statistical significance in maternal serum IgE titer using above 4 methods. However, the higher level of IgE titer was found in PRIST method when IgE was over 190 IU/ml(5 cases) estimated by PRIST method and in Overnight PRIST using RAST anti-IgE tracer method when Ig.E was below lgp IU/ml (16 cases) (p40.05). 2) In cord serum IgE titer, only Overnight PRIST using RAST anti-IgE tracer method showed statistical significance. 3) The most desirable correlation coefficient between maternal serum and cord serum IgE titer was estimated by Overnight PRIST using RAST anti-IgE tracer method than any other rnethods.