Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta: 2 case reports.
- Author:
Soonchang HONG
1
;
Jung Hwan KIM
;
Hee Jeong LEE
;
Young Nam YOUN
Author Information
1. Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Yonsei University Health System, Korea. ynyoun@yuhs.ac
- Publication Type:Case Report
- Keywords:
Aortic dissection;
Endovascular stent;
Aneurysm, dissection
- MeSH:
Aortic Rupture;
Endoleak;
Stents;
Transplants;
Treatment Failure;
Ursidae
- From:The Korean Journal of Thoracic and Cardiovascular Surgery
2010;43(6):758-763
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption.