Microleakage of the experimental composite resin with three component photoinitiator systems.
10.5395/JKACD.2009.34.4.333
- Author:
Ji Hoon KIM
1
;
Dong Hoon SHIN
Author Information
1. Department of Conservative Dentistry, College of Dentistry, Dankook University, Korea. donyshin@dankook.ac.kr
- Publication Type:Original Article
- Keywords:
Microleakage;
Composite resin;
Photoinitiation;
Electrical conductivity;
Thermocycling
- MeSH:
Barium;
Barium Compounds;
Bicuspid;
Composite Resins;
Electric Conductivity;
Glass;
Humans;
Light;
Polymers;
Silicon Dioxide;
Terpenes;
Tooth
- From:Journal of Korean Academy of Conservative Dentistry
2009;34(4):333-339
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 microm) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/cm2. Teeth were thermocycled five-hundred times between 50degrees C and 550degrees C for 30s at each temperature. Electrical conductivity (microA) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (microA)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.