Posterior Capsule Opacification and Intraocular Lens Design with In-the-bag fixated Posterior Chamber Lens.
- Author:
Ki Seok YOON
1
;
Dong Eul SHIN
Author Information
1. Department of Ophthalmology, Korea Veterans Hospital, Seoul, Korea.
- Publication Type:Original Article
- Keywords:
Biconvex lens;
Convex-plano lens with continuous laser ridge;
Inthe-bag placement;
Intraocular lens design;
Posterior capsule opacification(PCO)
- MeSH:
Capsule Opacification*;
Cataract;
Incidence;
Lasers, Solid-State;
Lenses, Intraocular*;
Posterior Capsulotomy;
Retrospective Studies
- From:Journal of the Korean Ophthalmological Society
1996;37(5):887-894
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
This study was performed to evaluate the correlationship between posterior capsular opacification and optic configuration of intraocular lens in extracapsular lens extraction with In-the-bag implantation of posterior chamber lens. We retrospectively studied the 455 cases of cataract operations that were performed between January 1993 and January 1995. All were in-the-bag placement and their optic designs were divided into two groups: a group of biconvex lens and a group of convex-plano lens with continuous laser ridge. The incidence of PCO in bicovex lens group was 7.0% and that of convex plano lens with laser ridge group was 7.1%. The difference in the rate of posterior capsular opacification between two groups was not statistically significant. The incidence of Nd: YAG laser posterior capsulotomy revealed 0.0% in continuous ridged group and 2.6% in biconvex group(p>0.05).