Use of a new low-profile coronary stent graft for the treatment of intracranial carotid blow-out
10.7461/jcen.2024.E2023.11.007
- Author:
Halil Ibrahim ALTUNBULAK
1
;
Ahmet Yasir ALTUNBULAK
;
Sinan BALCI
;
Mustafa BERKER
;
Anil ARAT
Author Information
1. Department of Radiology, Hacettepe University of Medicine of Faculty, Ankara, Turkey
- Publication Type:Case Report
- From:Journal of Cerebrovascular and Endovascular Neurosurgery
2024;26(4):399-404
- CountryRepublic of Korea
- Language:English
-
Abstract:
A 50-year-old male patient with a history of transcranial surgery and subsequent radiotherapy for a pituitary adenoma presented with repetitive pulsatile nasal bleeding. A right cavernous segment pseudoaneurysm was discovered on the angiogram, and the patient failed the balloon occlusion test. A Papyrus (Biotronik, Berlin, Germany) stent graft, which is approved for coronary interventions, was successfully deployed over a coaxial guiding system during the emergent treatment of the false aneurysm. The patient tolerated the procedure well and nasal bleeding did not recur after the procedure. At one-year angiographic follow-up, the stent graft was patent and there was no evidence of recanalization of the false aneurysm.