Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
10.16476/j.pibb.2024.0379
- VernacularTitle:三类斑迹多重荧光扩增体系的构建及应用研究
- Author:
Yi-Fan BAI
1
;
He-Miao ZHAO
2
;
Jing CHEN
2
;
Hong-Di LIU
2
;
Rui-Qin YANG
1
;
Chong WANG
2
Author Information
1. School of Criminal Investigation, People’s Public Security University of China, Beijing 100038, China
2. Key Laboratory of Forensic Biological Evidence, Institute of Forensic Science, Ministry of Public Security, Beijing 100038, China
- Publication Type:Journal Article
- Keywords:
forensic genetics;
body fluid stains;
mRNA
- From:
Progress in Biochemistry and Biophysics
2025;52(4):982-994
- CountryChina
- Language:Chinese
-
Abstract:
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.