Influencing factors for the accuracy of injection site selection for gastric varices under endoscopy
10.3760/cma.j.cn321463-20240206-00093
- VernacularTitle:内镜下胃静脉曲张注射点定位准确性的影响因素初探
- Author:
Lihong CHEN
1
;
Zhihong WANG
;
Xuecan MEI
;
Fumin ZHANG
;
Qianqian ZHANG
;
Chen SHI
;
Derun KONG
Author Information
1. 安徽医科大学第一附属医院消化内科 安徽省消化病重点实验室,合肥 230022
- Keywords:
Staining and labeling;
Endoscopic ultrasonography;
Indian ink;
Gastric varices
- From:
Chinese Journal of Digestive Endoscopy
2024;41(10):805-808
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare the accuracy of endoscopy and endoscopic ultrasonography (EUS) combined with Indian ink marking in locating injection sites for gastric varices, and to explore the influence of the features of gastric varices under endoscopy on the injection sites.Methods:Consecutive patients with gastric varices scheduled for EUS-guided glue injection therapy at the First Affiliated Hospital of Anhui Medical University from August 2021 to October 2022 were perspectively included. Firstly, gastric varices were assessed under endoscopy, where the size of the veins were estimated while the injection site was preliminarily judged during the procedure. Then EUS was used to identify perforating feeding veins and mark injection sites with Indian ink. After tissue adhesive was injected into identified varices, the change of varices after injection was observed and the marking was identified under endoscopy again. The clarity of the markinges was confirmed and the consistency between EUS-guided Indian ink mark and that under endoscopy was compared. Patients were divided into anastomosis group and non-anastomosis group based on marking consistency to investigate the effect of gastric varices features on the location of injection sites under endoscopy. Treatment efficacy and postoperative adverse events were counted.Results:Finally, 34 patients were included and all of them underwent successful marking under EUS guidance without complications. A total of 40 marker sites were clearly visible with Indian ink staining under endoscopy. The difference in distribution between the anastomotic group and non-anastomotic group marker points between EUS and endoscopy was statistically significant ( χ2=9.103, P=0.003). Vascular occlusion rate was 100.00% (40/40). There were 13 adverse events after operation, mainly fever, abdominal pain and nausea, and no serious adverse events such as allergy and ectopic embolization occurred. There was significant difference between the blood vessel diameter of the anastomotic group (10.84±4.02 mm) and that of the non-anastomotic group (8.80±1.61 mm, t=1.870, P=0.031). The percentage of raised vessels in the anastomotic group was 88.00% (22/25), higher than that in the non-anastomotic group [53.33% (8/15)], and the difference was statistically significant ( χ2=6.009, P=0.024). Conclusion:Accuracy in positioning under endoscopy is influenced by variceal diameter and bulge shape, being less precise in varices with smaller diameters and less pronounced bulges.