Clinical study of overlapping Wallstent stent implantation in large or giant extracranial internal carotid artery aneurysms
10.3760/cma.j.cn115354-20240827-00511
- VernacularTitle:Wallstent支架重叠植入治疗颈内动脉颅外段大型或巨大型动脉瘤的临床研究
- Author:
Qi TIAN
1
;
Shuailong SHI
;
Shuhai LONG
;
Ji MA
;
Ye WANG
;
Xiao LI
;
Renying MIAO
;
Yan SONG
;
Tengfei LI
Author Information
1. 郑州大学第一附属医院放射介入科,郑州大学介入治疗研究所,郑州 450052
- Keywords:
Extracranial internal carotid artery aneurysm;
Wallstent stent;
High-resolution C-arm CT;
Incomplete stent apposition
- From:
Chinese Journal of Neuromedicine
2024;23(11):1086-1093
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To assess the efficacy and safety of overlapping braided carotid artery stent (Wallstent) implantation in large extracranial internal carotid artery aneurysms (15 mm≤diameter<25 mm) and giant ones (diameter≥25 mm).Methods:A retrospective study was performed; the clinical data of 23 patients with large or giant extracranial internal carotid artery aneurysms accepted overlapping Wallstent stent implantation in Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from August 2015 to June 2023 were collected. Immediately after implantation, DSA was used to evaluate the retention of contrast agent within the aneurysms and high-resolution C-arm CT (HR-CBCT) was used to detect the apposition between the two stents and between the stents and inner wall of the blood vessel. Perioperative complications were recorded. Clinical follow-up was performed bi-monthly via outpatient visits or telephone, and modified Rankin scale (mRS) was used to assess the prognoses (mRS scores of 0-2 as good prognosis) at the last follow-up; aneurysm occlusion was evaluated in a 6-month follow-up by DSA and in-stent restenosis in a final imaging follow-up by DSA or CTA according to the OKM grading. Results:Twenty-two patients had successful overlapping implantation of 2 Wallstent stents; blood flow was restricted in one patient due to carotid artery dissection at the distal end of the aneurysm during stent implantation and restored after a Neuroform EZ stent and 2 Wallstent stent implantation from the distal-proximal lesion; technical success rate of 95.7% (22/23) was obtained. DSA immediately after implantation showed obvious contrast medium retention in all aneurysms. HR-CBCT indicated good stent apposition in 21 patients and mild incomplete stent apposition in 2. Clinical follow-up was finished in 23 patients, ranged 6-31 months (mean 11.5±6.3 months); all patients had good prognosis at the last follow-up. Imaging follow-up, including at least once DSA, was conducted for all patients, with intervals ranging from 6 to 15 months (mean 10.4±3.4 months); DSA 6 months after implantation showed complete aneurysm occlusion in 19 patients (OKM grading D) and a bit of residual contrast in 4 patients (OKM grading C); final imaging follow-up (DSA in 2 and CTA in 21) revealed in-stent stenosis in 2 patients (stenosis rates of 51% and 87%) with obvious improved stenosis after balloon angioplasty and patent stents in 21 patients without evidence of aneurysm opacification.Conclusion:Overlapping braided carotid artery stent (Wallstent) implantation is an effective and safe approach for managing large or giant extracranial carotid artery aneurysms.