Application of auto-prescription technique combined with noise index and iterative reconstruction algorithm to the computed tomographic angiography of deep inferior epigastric artery
10.3760/cma.j.cn112271-20230713-00002
- VernacularTitle:自动预置技术结合噪声指数及迭代重建算法在腹壁下动脉CT血管成像中的应用
- Author:
Mengting HU
1
;
Shigeng WANG
;
Xiaoyu TONG
;
Yong FAN
;
Jingyi ZHANG
;
Qiye CHENG
;
Anliang CHEN
;
Yijun LIU
Author Information
1. 大连医科大学附属第一医院放射科,大连 116011
- Keywords:
Epigastric artery;
CT angiography;
Radiation dose
- From:
Chinese Journal of Radiological Medicine and Protection
2024;44(5):436-442
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the effects of the auto-prescription technique combined with noise index (NI) and adaptive statistical iterative reconstruction algorithm-veo (ASIR-V) on the radiation dose and image quality in the computed tomographic angiography (CTA) of the deep inferior epigastric artery (DIEA).Methods:The data of 150 cases who underwent DIEP CTA in the First Affiliated Hospital of Dalian Medical University were prospectively collected, and were randomized into groups A, B, and C, with 50 cases in each group. For group A, the conventional tube voltage was 120 kVp, and images were reconstructed using 40% ASIR-V. For group B, the tube voltage based on the auto-prescription technique was adopted, and images were reconstructed using 40%, 60%, and 80% ASIR-V (corresponding to the three subgroups B1-B3, respectively). For group C, the tube voltage based on the auto-prescription technique was employed, NI = 13, and images were reconstructed by 40%, 60%, and 80% ASIR-V (corresponding to subgroups C1, C2, and C3, respectively). Subsequently, the CT and SD values of the originating femoral artery of DIEA and the rectus abdominis at the same level as DIEA were measured on axial images of each group, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and the radiation doses of the three groups were recorded. Finally, the image quality and noise of DIEA in each group were independently and subjectively scored by two radiologists in a blinded manner.Results:Compared to group A, groups B and C exhibited higher CT values of femoral artery ( t= -5.18, -5.17, -5.06, -6.08, -6.08, -6.07, P < 0.05) and higher image SNR and CNR ( P < 0.05), which increased gradually with the upgrading of ASIR-V ( F = 55.45, 49.70, 53.47, 68.89, P < 0.05). The two radiologists offered consistent subjective evaluations (Kappa = 0.76-0.92, P < 0.05). The images of groups B and C displayed more distinct perforating branches and emerging points of DIEA and received higher subjective scores of intramuscular course compared to those of group A. The subjective scores of image noise in subgroups B2, B3, and C2 were not significantly different from those in group A. The radiation doses in groups B and C decreased by 15.10% and 52.85%, respectively compared to those in group A ( H = 75.21, P < 0.05). Conclusion:The combination of the auto-prescription technique with NI = 13 and 60% ASIR-V can reduce the radiation dose by 52.85% while ensuring a clear display of DIEA.