Ultrasonographic measurements of intracranial markers related to central nervous system of normal fetuses in early pregnancy in Suzhou
10.3760/cma.j.cn131148-20240509-00274
- VernacularTitle:苏州地区正常早孕期胎儿中枢神经系统相关颅内指标正常值的超声研究
- Author:
Lingling SUN
1
;
Jiaojiao CAO
;
Jun ZHANG
;
Chunya JI
;
Qi PAN
;
Zhong YANG
;
Chen LING
;
Xuedong DENG
;
Linliang YIN
Author Information
1. 南京医科大学附属苏州医院 苏州市立医院超声中心,苏州 215002
- Keywords:
Ultrasonography, first trimester;
Central nervous system;
Fetus;
Malformation;
Markers;
Normal reference range
- From:
Chinese Journal of Ultrasonography
2024;33(11):975-982
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To establish reference ranges of central nervous system-related fetal intracranial markers during the first trimester in a local population of Suzhou.Methods:Ultrasound images of fetuses with normal birth outcomes in singleton pregnancies who underwent nuchal translucency(NT) screening during the first trimester (11-13 + 6 gestational weeks) from January 2021 to July 2022 at the Affiliated Suzhou Hospital of Nanjing Medical University were retrospectively selected. The images including 3 planes: the midsagittal plane of the fetal head, also known as the plane for NT measurement, the trans-ventricular plane of the fetal head, and the axial plane of the fetal head at the posterior fossa level. The brainstem (BS) thickness, brainstem to occipital bone distance (BSOB), the ratio of BS to BSOB (BS/BSOB), intracranial translucency (IT) thickness, cisterna magna (CM) width, and the midbrain (MB) to falx (F) ratio MB/F were measured in the mid-sagittal plane of the fetal head. Choroid plexus length (CPL) to occipital frontal diameter (OFD) ratio CPL/OFD, and choroid plexus area (CPA) to head area (HA) ratio CPA/HA were measured in the trans-ventricular plane of the fetal head. Anteroposterior diameter of the fourth ventricle (4V) and CM were measured in the axial plane of the fetal head at the posterior fossa level.Statistical analysis was performed to obtain the corresponding normal reference range.Intra-class correlation coefficient (ICC) was used to analyze intra-observer and inter-observer consistency. Pearson correlation analysis and linear correlation analysis were used to study the correlations between crown-lump length (CRL) and intracranial markers, and the regression equation was derived. Results:A total of 2 331 fetuses were enrolled, providing 1 023 images of the midsagittal plane, 817 images of the trans-ventricular plane, and 567 images of the axial plane of the fetal head at the posterior fossa level. The intra-observer and inter-observer ICCs of intracranial markers BS, BSOB, BS/BSOB, IT thickness, CM width, MB/F in the mid-sagittal plane, the intracranial markers CPL/OFD, CPA/HA on the trans-ventricular plane, and the intracranial markers 4V and CM width in the axial plane at the posterior fossa level were all >0.75. Fetal intracranial markers were linearly correlated with CRL. The midsagittal plane: BS, BSOB, BS/BSOB, IT thickness, CM width, MB/F were linearly correlated with CRL ( r=0.508, 0.626, -0.234, 0.105, 0.508, -0.493; all P<0.05); the trans-ventricular plane: CPL/OFD, CPA/HA were linearly correlated with CRL( r=-0.324, -0.268; all P<0.001); the axial plane of the fetal head at the posterior fossa level: 4V, CM width were linearly correlated with CRL ( r=0.246, 0.467; all P<0.001). Conclusions:Quantitative analysis of fetal intracranial markers in the first trimester is feasible. This study constructed a normal reference range of multiple intracranial markers related to central nervous system in the first trimester with a local population of Suzhou. And the construction of this normal range can provide an objective basis for the detection of fetal central nervous system malformations in the first trimester.