Comparison of diagnostic performance of adding value of transabdominal and transvaginal contrast-enhanced ultrasound to Ovarian-Adnexal Reporting and Data System Ultrasound risk stratification in the evaluation of adnexal masses
10.3760/cma.j.cn131148-20240113-00035
- VernacularTitle:经腹部与经阴道超声造影联合超声卵巢-附件报告和数据系统诊断附件肿物的对比研究
- Author:
Manli WU
1
;
Manting SU
;
Ruili WANG
;
Xiaofeng SUN
;
Rui ZHANG
;
Liang MU
;
Li XIAO
;
Hong WEN
;
Tingting LIU
;
Xiaotao MENG
;
Xinling ZHANG
Author Information
1. 中山大学附属第三医院超声科,广州 510630
- Keywords:
Contrast-enhanced ultrasound;
Ovarian-Adnexal Reporting and Data System;
Adnexal mass;
Differentiation diagnosis
- From:
Chinese Journal of Ultrasonography
2024;33(5):385-391
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To compare and explore the diagnostic performance of adding value of transabdominal and transvaginal contrast-enhanced ultrasound (CEUS) to Ovarian-Adnexal Reporting and Data System (O-RADS US) risk stratification and management system in differential diagnosis of adnexal masses.Methods:A total of 180 adnexal masses with solid components in 175 women were enrolled retrospectively between September 2021 and November 2022. All patients underwent routine Doppler ultrasound examinations and CEUS examinations. Among these masses, 107 masses underwent with transabdominal CEUS, 58 masses underwent with transvaginal CEUS, and 15 masses underwent both transvaginal and transabdominal CEUS. All patients were scheduled for surgery and pathological results served as the reference standard. Routine Doppler ultrasound and CEUS images and video were reviewed by a subspecialty radiologist using Vuebox software. The O-RADS US was downgraded or upgraded according to the CEUS characteristics of the masses. The diagnostic accuracy was assessed using ROC curve analysis. The area under the ROC curve (AUC) was calculated to compare the diagnostic performance of adding value of transabdominal and transvaginal CEUS to O-RADS US.Results:The diagnostic performance of adding transabdominal and transvaginal CEUS to O-RADS US were both significantly higher than of O-RADS US alone (transabdominal CEUS: AUC 0.83 vs 0.76, P=0.018; transvaginal CEUS: AUC 0.92 vs 0.81, P=0.013). Combination of transvaginal CEUS and O-RADS US was superior to that of combination of transabdominal and O-RADS US in the differential diagnosis of adnexal masses ( P=0.047). When the maximal diameter of adnexal masses ≤40 mm, transabdominal combined with O-RADS US presented the lowest diagnostic performance, with an AUC of 0.73. Conclusions:Combination of transvaginal CEUS and O-RADS US was superior to that of combination of transabdominal and O-RADS US in assessing adnexal masses with solid components. When the maximal diameter of adnexal masses ≤40 mm, transvaginal CEUS examination was recommended.