Screw placement assisted by robotic navigation in cannulated screw fixation for fracture of scapular coracoid process
10.3760/cma.j.cn115530-20240328-00135
- VernacularTitle:机器人导航辅助置钉在空心螺钉固定治疗肩胛骨喙突骨折中的应用
- Author:
Chen WANG
1
;
Hu PAN
;
Chen FEI
;
Wuqiang JIANG
;
Lei LEI
;
Fan XU
;
Aiming YE
;
Zhan WANG
;
Kun ZHANG
;
Zhe SONG
;
Wei FAN
Author Information
1. 西安交通大学附属红会医院创伤骨科,西安 710054
- Keywords:
Robotics;
Scapula;
Coracoid process fractures;
Fracture fixation, internal;
Bone nails
- From:
Chinese Journal of Orthopaedic Trauma
2024;26(9):804-809
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the screw placement assisted by robotic navigation in cannulated screw fixation for treatment of fracture of scapular coracoid process.Methods:A retrospective study was conducted to analyze the data of 24 patients with fracture of scapular coracoid process who had been treated by cannulated screw fixation at Department of Orthopaedics and Trauma, Red Cross Hospital Affiliated to Xi'an Jiaotong University from January 2020 to December 2023. According to whether the intraoperative screw placement was assisted by robotic navigation or not, the patients were divided into 2 groups. In group A of 11 cases, there were 6 males and 5 females with an age of (47.4±3.4) years whose screw placement was assisted by robotic navigation during the internal fixation with cannulated screws. In group B of 13 cases, there were 10 males and 3 females with an age of (43.5±4.9) years whose screw placement was assisted by conventional C-arm X-ray fluoroscopy during the internal fixation with cannulated screws. The operative time, intraoperative blood loss, fracture healing time, intraoperative fluoroscopy frequency, intraoperative adjustments of guide wire, Constant-Murley score of shoulder function at the last follow-up and postoperative complications were compared between the 2 groups.Results:There was no significant difference in the preoperative general data between the 2 groups, indicating comparability ( P>0.05). The follow-up time was (25.3±9.1) months for group A and (27.6±10.8) months for group B, showing no statistically significant difference ( P>0.05). The intraoperative blood loss [(51.8±35.7) mL], intraoperative fluoroscopy frequency [(5.7±1.0) times] and intraoperative adjustments of guide wire [(1.6±0.7) times] in group A were significantly less than those in group B [(123.8±73.9) mL, (12.5±2.7) times, and (5.3±1.0) times] ( P<0.05). There were no significant differences in operative time [(88.2±21.3) min versus (80.4±31.1) min], fracture healing time [(10.0±1.3) weeks versus (11.5±2.7) weeks] or Constant Murley score of shoulder function at the last follow-up [(86.7±6.1) points versus (91.1±10.0) points] between group A and group B ( P>0.05). No patient reported such complications as wound infection, fracture nonunion, or failure of internal fixation during the follow-up period. Conclusions:In the treatment of fracture of scapular coracoid process by cannulated screw fixation, robotic navigation can be used to assist screw placemen to achieve good efficacy comparable to conventional C-arm X-ray fluoroscopy. Moreover, assistance by robotic navigation can help reduce intraoperative blood loss and radiation, and improve surgical accuracy.