Research on intelligent control management of medical magnetic resonance imaging equipment based on multi-constraint optimal programming model
10.3969/j.issn.1672-8270.2024.10.021
- VernacularTitle:基于多约束条件最优规划模型的医疗磁共振成像设备智能质量控制管理研究
- Author:
Han SONG
1
;
Yexiang CHEN
;
Huan MIAO
;
Keshou WANG
Author Information
1. 东南大学附属中大医院溧水分院总务科 南京 211200
- Keywords:
Optimal programming model;
Magnetic resonance imaging equipment;
Quality control management;
Constraints
- From:
China Medical Equipment
2024;21(10):112-117
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To study the quality control management method of magnetic resonance equipment based on multi-constraint optimal programming model,and to improve the utilization efficiency and imaging effect of magnetic resonance imaging(MRI)equipment.Methods:By gridding the current carrying area of the superconducting magnet of magnetic resonance equipment,the total length of the superconducting material was calculated,and the optimal programming model of the magnetic resonance superconducting magnet was established with constraints set.The optimal programming results of the superconducting magnet was obtained by solving the model to achieve quality control of the magnetic resonance equipment.Taking the minimum scanning time of magnetic resonance equipment as the objective function,a refined management model of magnetic resonance equipment was established to realize the time planning for the use of magnetic resonance equipment.Using fuzzy set theory,the six magnetic resonance equipment in clinical use in Lishui Branch of Zhongda Hospital Southeast University from 2022 to 2023 was divided into five grades according to the imaging quality of magnetic resonance equipment,including excellent,good,average,below average and poor.The quality control management effect was evaluated from the uniformity of the superconducting magnet imaging magnetic field,the uniformity of 10 magnetic resonance images,the geometric distortion rate,and the total number of monthly scans.Results:After the implementation of the quality control management method for magnetic resonance equipment based on the multi-constraint optimal programming model,the maximum value of the magnetic field uniformity contour of the tested equipment was reduced from 15 ppm to 5 ppm;the uniformity test results of the 10 collected magnetic resonance images showed that 2 were good and 8 were excellent,all of which met the technical standards of magnetic resonance imaging;the mean value of geometric distortion rate of magnetic resonance imaging was at-0.5%~0,and the corresponding test grade was excellent;the number of monthly scans of the human body by the tested magnetic resonance equipment was higher than that before the quality control management,especially the number of lower limb scans increased from 607 times before the quality control management to 821 times,with an increase of 214 times.Conclusion:The quality control management method for magnetic resonance equipment based on multi-constraint optimal programming model can effectively improve the quality and control management level of magnetic resonance equipment,optimize the maintenance and management process of magnetic resonance equipment,improve equipment operation efficiency,and reduce operating costs.