Study on the protection of ABC technique for heart and its substructures in radiotherapy for left breast cancer
10.3969/j.issn.1672-8270.2024.07.003
- VernacularTitle:自主呼吸控制技术在左侧乳腺癌放疗中对心脏及其亚结构的保护研究
- Author:
Hongtao CHEN
1
;
Weisi CHEN
;
Ying PIAO
;
Fang ZHENG
;
Yabin SHI
;
Dong YANG
;
Zihuang LI
Author Information
1. 深圳市人民医院(暨南大学第二临床医学院 南方科技大学第一附属医院)肿瘤放疗科 深圳 518020
- Keywords:
Respiratory movement management;
Active breathing coordinator;
Left breast cancer;
Cardiac substructure;
Intensity modulated radiotherapy(IMRT)
- From:
China Medical Equipment
2024;21(7):23-28
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the protection of Active Breathing Coordinator(ABC)technique for heart and its substructures in radiotherapy for left breast cancer.Methods:A total of 50 patients with left breast cancer who underwent radiotherapy in our department were retrospectively selected,and treatment plans with intensity modulated radiotherapy(IMRT)were designed on the images of ABC combined with deep inspiration breath hold(ABC-DIBH)computed tomography(CT)and free-breathing(FB)CT,respectively.The dose parameters of the organ at risks(OARs)of heart and its substructures,including left ventricle(LV),left atrium(LA),right ventricle(RV),right atrium(RA),left main coronary artery(LMCA),left anterior descending coronary artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA),were compared between the two conditions.Results:Compared with FB,the dose of 2%volume(D2),the mean dose(Dmean),the percent volumes covered by different doses(V30,V20,V10,V5)decreased respectively 32.91%(absolute reduction of 1279.11 cGy),36.12%(195.94cGy),58.95%(2.8%),54.32%(3.58%),50.14%(5.56%)and 46.22%(9.67%)of heart under ABC-DIBH condition,and the differences were significant(t=10.28,12.81,9.16,10.28,12.82,12.24,P<0.01),respectively.In addition,the Dmean values of LV,LA,RV,RA,LMCA,LAD,LCX and RCA decreased by 37.64%(absolute reduction was 285.92 cGy),15.38%(23.68 cGy),34.12%(118.93cGy),9.72%(12.52 cGy),22.17%(47.99 cGy),31.81%(820.63 cGy),16.51%(34.72 cGy)and 14.86%(34.11cGy)under ABC-DIBH condition,respectively,the differences were significant(t=9.50,3.71,6.20,8.65,3.18,10.92,4.26,6.71,P<0.05).Conclusion:ABC technique can greatly reduce the received doses of heart and its substructures by extending the distance between the heart and the target region with DIBH,thus can form a very effective protection for the heart and its substructures.In addition,it can eliminate the dynamic variation of target location of breast cancer caused by respiratory,and avoid a series of problems,such as target missing,overexposure on normal tissue,and dose deviation.