Clinical value of compression rate combined with Young's modulus value in assessing median nerve injury of patients with dialysis
10.3969/j.issn.1672-8270.2024.05.021
- VernacularTitle:压缩率联合杨氏模量值对评估透析患者正中神经损伤的临床价值
- Author:
Qian ZHOU
1
;
Ling YU
;
Li KANG
;
Ruijun GUO
;
Huiyu GE
Author Information
1. 首都医科大学附属北京朝阳医院超声医学科 北京 100020
- Keywords:
Compression ratio;
Young's modulus;
Dialysis;
Amyloidosis;
Median nerve injury
- From:
China Medical Equipment
2024;21(5):107-111
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the clinical value of compression rate(CR)of median nerve combined with Young's modulus value(E)in quantitatively evaluating median nerve injury of patients with dialysis-related amyloidosis(DRA).Methods:A retrospective analysis was conducted on 53 maintenance hemodialysis(HD)patients who admitted to department of blood purification of Beijing Chao-Yang Hospital of Capital Medical University from November 2019 to October 2020,and they were divided into case group,and 60 volunteers who underwent physical examination at the outpatient of the department of ultrasound medicine were selected as healthy control group.Basic clinical data of the patients were collected.Based on the results of physical examination,the patients with dialysis were divided into a sign group(n=18)and a non-sign group(n=35).High-frequency ultrasound was used to measure the anteroposterior diameter of the median nerve at the entrance of the carpal tunnel and the protrusion of the distal radius in all subjects.The CR values of anteroposterior diameters were calculated.Shear Wave Velocity elastography(SWE)technique was employed to measure E values of the median nerves of compressed position.The differences in CR and E values between case group and healthy control group,as well as between sign group and non-sign group were respectively compared and analyzed.Furthermore,the diagnostic efficacies of CR alone,E value alone and their combination for median nerve injury were evaluated.Results:The CR and E values of median nerve of cases group were respectively(0.16±0.01)and(104.49±49.42)kPa,and they were respectively(0.07±0.05)and(42.47±15.64)kPa in health control group.The CR and E values of median nerve in case group were significantly higher than those in health control group(t=4.92,6.39,P<0.001),respectively.The CR and E values of the median nerve in the sign group of cases group were respectively(0.31±0.09)and(150.58±47.71)kPa,and those in the non-sign group of case group were respectively(0.10±0.09)and(87.95±38.73)kPa.The CR and E values of median nerve of the sign group were significantly higher than those in the non-sign group(t=7.78,4.89,P<0.001),respectively.The duration of the disease was positive correlation with E value and CR value of median nerve in HD patients who underwent dialysis(r=0.598,0.459,P<0.001),respectively.The area under curve (AUC) value of receiver operating characteristic (ROC) curve showed that the best CR cut-off value was 21% and the E value was 76.22kpa in diagnosing median nerve injury,.and the AUC values of CR and E value were respectively 0.844 and 0.817,and the AUC value,sensitivity and specificity of the combine of them reached respectively 0.908,100% and 89%. Conclusion:Both CR and E values of the median nerve can be used to evaluate the median nerve injury in patients with DRA,and the combination of them has a higher diagnostic efficiency. Conventional ultrasound and SWE elastography can be the preferred imaging methods for the evaluation of median nerve injury.