Establishing Multi-Modal Ultrasound-Based Prediction Model for Placental Insufficiency of Second Trimester
10.3969/j.issn.1005-5185.2024.08.013
- VernacularTitle:基于多模态超声对中孕期胎盘功能不全预测模型的建立
- Author:
Huan LI
1
;
Bing HU
;
Pengfei CHE
;
Lili HU
;
Xiaowei XIANG
Author Information
1. 三峡大学附属仁和医院超声科,湖北 宜昌 430001
- Keywords:
Placental insufficiency;
Ultrasonography;
Logistic model;
Second trimester;
Multi-modal
- From:
Chinese Journal of Medical Imaging
2024;32(8):828-833
- CountryChina
- Language:Chinese
-
Abstract:
Purpose Using conventional ultrasound,3D energy Doppler and shear wave elastography to develop one multi-modal ultrasound-based prediction model for placental insufficiency of second trimester.Materials and Methods A prospective analysis was conducted by reviewing 209 pregnant women with anterior wall placenta who underwent multi-modal ultrasound examination in the Affiliated Renhe Hospital of China Three Gorges University from April 2021 to April 2022,and all participants were divided into 118 cases in the normal group and 91 cases in the placental insufficiency group based on clinical diagnosis.Their placental function was evaluated through hemodynamics[blood flow parameters of umbilical artery(UA),uterine artery(Ut A)and cerebral placental rate(CPR)],blood stream perfusion[vascular index(VI),blood flow index(FI)and vaso-blood flow index(VFI)]and mechanical tissue properties[mean of elasticity modulus(Emean)].Logistic regression analysis was performed on the indicators with statistically significant differences between groups,establishing a prediction model of placental insufficiency and evaluating its efficacy.Results There were statistically significant differences in Ut A blood flow parameters,CPR,VI,VFI and Emean between the two groups(t=-12.74,-10.28,-11.01,7.02,7.00,-11.97,all with P<0.05).In regression analysis,Ut A-RI(≥0.65),CPR(≤1.53)and Emean(≥4.14 KPa)were found to be the independent risk factors,of which Emean had the greatest diagnostic efficacy(area under the curve,AUC=0.904).The AUC of the prediction model established by combining the three parameters was 0.945,with a sensitivity of 87.91%and a specificity of 94.92%,which has significantly higher diagnostic efficacy than that of a single parameter.Conclusion The prediction model based on the multi-modal ultrasound parameters has certain predictive value and high specificity for placental insufficiency of second trimester and can guide early clinical intervention to improve perinatal outcomes.